7 - DIAGNOSIS

7.1

TROUBLESHOOTING

The possible problems and solutions concerning the machine in question are given below.
The following operations can be carried out by the operator, following an adequate training
and knowledge of this manual.
Contact the manufacturer, in case of different situations from those described.
PROBLEMS
The machine does not switch-on
The machine switches on but does not
start: the display shows one of the
alarm messages
The compressor starts but almost
immediately stops: the display shows
"E06 + P MAX"
The machine works but the mix does
not the preservation temperature: the
work cycle does not interrupt and the
wording "E16 + TMAX F" appears
Ice or thick mix crust formed on the
tank walls
Mix leaking from tap on external wall
Water leaking from hose spray
THIS MANUAL IS THE PROPERTY OF
POSSIBLE CAUSES
1. Power supply plug not correctly
inserted
2. Faulty current socket or plug
3. Interrupted fuse
4. Faulty power supply cable
See Table 7.1
Pressure switch intervention due to
cooling water flow interruption
1. Temperature probe not working
2. Faulty control board
3. Discharged refrigerator system
1. Stirrer block or malfunctioning
2. Mix quantity below the prescribed
minimum (20 l)
Missing, ruined or badly assembled
gaskets and O-Rings
Broken flexible hose or damaged
gaskets
TECHNOGEL SpA
ALL REPRODUCTIONS, EVEN PARTIAL, ARE FORBIDDEN
36
Page 36 of 52
REMEDY
1. Insert the plug in the socket
properly
2. Faulty current socket or plug
3. Change the broken fuse
4. Change the power supply cable
See Table 7.1
Check water tap opening
Check the water supply line is not
obstructed.
Call the Technical Assistance if the
problem persists
Request the Technical Assistance
intervention
1. Check the stirrer is properly
inserted; check the control shaft
regularly turns, if not, contact the
Technical Assistance
2. Completely discharge the tank
Check assembly and eventually
replace the tap gaskets
Replace the hose and/or tap of hose
spray