4.3.1
Work areas (machine running)
The work area is near the front control and product supply panel from where the machine functioning can be
controlled and managed.
4.3.2
Work areas (maintenance)
The areas set-up for machine maintenance, for performing maintenance and/or adjustments of the different
mechanical/electrical activation devices, are all around the machine.
4.3.3

Dangerous areas

Dangerous areas are:
-
the entire work area inside and outside the machine, where the work phases occur;
-
all areas protected by the specific protective devices composed by the machine casing.
4.4
DANGERS AND RESIDUAL RISKS
ATTENTION
The operator must consider the residual risks described in the following table and adopt
the adequate measures, during machine use.
1. The operator must carefully read the use and maintenance instructions before using the machine. The
operator must be adequately trained on the machine functioning and methods to guarantee its safe use.
In particular, he must be aware of the residual risks present and on the methods to prevent dangerous
situations thereto related.
2. Install the machine in an environment that does not create risks for the operator while interacting with
the machine.
3. Prevent product pollution (ice cream mix) by the environment air or machine parts, by running the
machine in environments conforming with the proper health and hygiene procedures and guarantee the
prescribed cleaning and sanitising cycles.
4. The operator must be cautious during maintenance (e.g. dismantling of lid, tap, etc.) to avoid the falling
of machine parts. The operator must, therefore, always have the prescribed PPE when near the
machine.
5. Contact with hot or cold machine parts (e.g. discharge tap, tank and its lid) is possible during functioning
and maintenance: said contact only occurs in case of operator intervention during intermediate phases
of the normal work cycle. The same risk applies for contact with the product being processed. The use
of adequate PPE is prescribed (gloves)
6. The electric power supply consists of the red connection plug (isolator identified with socket/plug
system): it must be easy for the operator to identify it and disconnect it from the normal work station.
7. Pay attention not to trip on the power supply cable that must be properly highlighted or protected with a
treadable duct.
8. Clean and sanitise the machine using products compatible with food use.
9. It is forbidden to run the machine in an explosive environment. The machine must not be run in
uncovered areas, exposed to atmospheric agents (e.g. lightning).
THIS MANUAL IS THE PROPERTY OF
RESIDUAL RISKS OF THE MACHINE
TECHNOGEL SpA
ALL REPRODUCTIONS, EVEN PARTIAL, ARE FORBIDDEN
26
Page 26 of 52

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Technogel Mixpasto 60

This manual is also suitable for:

Mixpasto 120

Table of Contents