3DJH 
([DPSOH selection of all test data for the month of December in the year 2000:
3ULQWLQJ D WDEXODU VXPPDU\ RI WHVWV
By taking the following steps, you can print a tabular summary of all tests stored in
the instrument:
c
Make sure that the printer is connected and switched on.
d
Change from PHQX  to the sub-menu RXWSXW by pressing the function button I, and
then use function button I to select the sub-menu WDEOH
e
Enter selection criteria for the date, sample code and sample status as described
above, and close your entries by pressing the PHP button. The printer will now start
to print.
The print-out has six columns:
If no post-test parameters have been entered (see Section 8.2), the remark 37 SD
UDPHWHUV PLVVLQJ will be printed instead of the net calorific value; The net calorific
value can only be calculated with the aid of post-test parameters. If pre-test pa-
rameters have been entered but a test not yet carried out, the remark QR PHDVXUH
PHQW SHUIRUPHG \HW will be printed.
At the end of the summary of tests, the C values of the decomposition vessels will
be printed. If a decomposition vessel has not been calibrated, or if the data were
entered manually, this is indicated.
,QIRUPDWLRQ DERXW IUHH PHPRU\
The calorimeter can store a maximum of 100 tests. Using the following procedure,
you can find out at any time how much memory is still available for further tests.
c
Change from PHQX  to the sub-menu RXWSXW by pressing the function button I, and
then use function button I to select the sub-menu IUHH. The message [ WHVWV IUHH
appears, where [ is the number of tests still free. An acoustic signal sounds at the
same time.
d
Acknowledge this message by pressing the
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
the selection criterion for the date is "
th
month, the 12
. month, and the year 2000 will be selected;
the selection criterion for the sample code is "
the tests stored in the instrument will be selected;
the selection criterion for the sample status is DOO so that, as before, all the tests
stored in the instrument will be selected.
VDPSOH FRGH sample code, under which all data for the test are stored
%1R
number of the decomposition vessel used for the test
GDWH
date on which the test was carried out
P >J@
sample mass in grams
+R >-J@
gross calorific value in Joules per gram
+X >-J@
net calorific value in Joules per gram
 
1200". In this way, all the days of the

", so that the sample codes of all
9
button.
®
IKA
-WERKE C 7000
 (YDOXDWLRQ RI &DORULILF 9DOXH 7HVWV