Tools - Proxim Tsunami MP-8100 Series Installation And Management Manual

Hide thumbs Also See for Tsunami MP-8100 Series:
Table of Contents

Advertisement

NOTE: A recording interval from one to sixty minutes with 5-minute increments can be selected. If we configure the
logging interval as "0", temperature logs will be disabled.
To view and configure threshold values and the logging interval, click MONITOR > Logs > Temperature Log.
The threshold values of temperature are to be configured in Centigrade (Celsius) scale. Current Unit Temperature in Celsius
can be seen along with the links to display the temperature log and to clear the logs, in the figure. The temperature log can
have the maximum size of 65 kb; and once the limit is reached, only the last 576 logs will be available. (Log storage is up to
six days with the refresh time of 5 minutes).

6.8 Tools

6.8.1 Link Test
WORP Link Test shows, in graphical form, Signal and Noise levels at which packets are received at local and remote unit.
WORP link test feature is used to monitor the local/remote signal/noise/SNR details of the connected WORP link. During
antenna alignment, this feature can be enabled to monitor the min/cur/max signal details.
NOTE: Internet Explorer 6.0 and its above versions support the link tests.
Tsunami MP-8100 Installation and Management Guide
Figure 6-17 Temperature Log
Monitoring the System
164