DigiLinX Installation and Design Guide

Procedures

3-2
All specifications subject to change without notification. All rights reserved. Copyright © 2008 NetStreams
To terminate wires, use the 568a standard (see Table 3-1).
Table 3-1
Ethernet 568a Standard for
Terminating Wires
Pin 1
White/Green
Pin 2
Green
Pin 3
White/Orange
Pin4
Blue
Pin 5
White/Blue
Pin 6
Orange
Pin 7
White/Brown
Pin 8
Brown

Example

Figure 3-1 shows an example of how to pre-wire a room for DigiLinX audio.
This diagram is a general overview of audio pre-wiring and is subject to change
NOTE:
depending on the design of the system. This pre-wire will allow you to grow with technology.
Figure 3-1
Pre-Wiring Diagram for DigiLinX
The following pre-wire procedure is designed to allow DigiLinX or Musica to later be
installed. To pre-wire a room, complete the following steps:
From the head end, run a siamese CAT5 16/4 (or CAT5 14/4) cable to the touch
1.
screen location.
Leave a service loop at this location and continue (do not cut the cable) to the first
2.
speaker location in the room.
Leave a service loop at this location and continue (do not cut the cable) to the
3.
second speaker location.
Cut the cable.
4.
From the touch screen location, run a siamese CAT5 16/4 (or CAT5 14/4) cable to
5.
the first speaker location.
Leave a service loop and continue (do not cut the cable) using a different route to
6.
the wall location chosen for the Audio Port installation.
Cut the cable.
7.
From the head end, run an RG6 cable to the touch screen location.
8.
From the head end, run an RG6 cable to a location for an antenna to be mounted.
9.
This will be used for antenna distribution.
From the head end, run a siamese 16/4 or 14/4 cable to the display location.
10.
From the head end, run a standard structured wiring bundle (2 CAT5, 2 RG6) to the
11.
display location.
Run an RG6 cable from the display location.
12.