Jumper Settings
X
Panel Power Select
The power level supplied to the LVDS/eDP panel can be switched between +3.3V, +5V or +12V
via JP10.
2
4
6
1
3
5
„ 1-2 On: +12V
„ 3-4 On: +5V
Important:
Before powering-on the system, make sure that the setting of JP10 matches the
specifications of the LVDS/eDP LCD. Incorrect power voltage may cause irrevers-
ible damage to your LCD panel.
User's Manual | AL102
JP8
2
4
6
2
4
6
1
3
5
1
3
5
„ 5-6 On: +3.3V (default)
Jumper Settings
X

KB/MS Power Select

The power level supplied to the KB/MS connector can be switched between +5V or +5VSB via
JP14.
3
2
1
„ 1-2 On: +5VSB (default)
Note:
To enable Wake On KB/MS, please set the jumper to +5VSB.
Chapter 2
HARDWARE INSTALLATION
JP14
3
2
1
„ 2-3 On: +5V