YASKAWA SI-EM3 Installation Manual page 48

Ac drive option modbus tcp/ip
Hide thumbs Also See for SI-EM3:
Table of Contents

Advertisement

7 Modbus TCP/IP Messaging
Drive
Address
Register
(hex)
(hex)
2009
C0
200A
C1
48
Description
Bit
Error Signal 1
A
B
C
D
E
F
Error Signal 2
A
B
C
D
E
F
YASKAWA ELECTRIC TOBP C730600 91D YASKAWA AC Drive Option SI-EM3 Installation Manual
0
Reserved
1
Undervoltage (Uv1)
2
Control Power Supply Undervoltage (Uv2)
3
Soft Charge Circuit Fault (Uv3)
4
Short Circuit / IGBT Failure (SC)
5
Ground Fault (GF)
6
Overcurrent (oC)
7
Overvoltage (ov)
8
Heatsink Overheat (oH)
9
Heatsink Overheat (oH1)
Motor Overload (oL1)
Drive Overload (oL2)
Overtorque Detection 1 (oL3)
Overtorque Detection 2 (oL4)
Dynamic Braking Transistor Fault (rr)
Braking Resister Overheat (rH)
0
External Fault at input terminal S3 (EF3)
1
External Fault at input terminal S4 (EF4)
2
External Fault at input terminal S5 (EF5)
3
External Fault at input terminal S6 (EF6)
4
External Fault at input terminal S7 (EF7)
5
External Fault at input terminal S8 (EF8)
6
Cooling fan Error (FAn)
7
Overspeed (os)
8
Excessive Speed Deviation (dEv)
9
PG Disconnected (PGo)
Input Phase Loss (PF)
Output Phase Loss (LF)
Motor Overheat (PTC input) (oH3)
Keypad Connection Fault (oPr)
EEPROM Write Error (Err)
Motor Overheat Fault (PTC input) (oH4)