4-26
DURADRIVE HDC01.1 Drive Controller

X1, Connections for Control voltage

Illustration
Connection cross section
Connection
+24V and 0V
Connection loads
+24V and 0V
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Technical description of connector
Fig. 4-34:
connector X1
Design
Type
Screw terminal
Fig. 4-35:
Design
Cross section
single wire
[mm²]
0,2-4
Fig. 4-36:
Connection cross section
24V control voltage supply (+24V and 0V)
Fig. 4-37:
Connections for control voltage
Voltage at X1/+ against X1/-:
Reverse voltage protection:
Current or power consumption X1/1:
Note:
Always use a shielded cable for connection. Connect the
shield to XS1, XS2 or XS3.
AP5356F1.FH7
No. of pins
6
Cross section
multi core wire
[mm²]
0,2-4
device-external
1
2
connection for
3
control voltage
4
5
feedback
6
power contactor
XS
DURADRIVE Drive Controllers
Design
Bushing on connector
Cross section
in AWG
Gauge no.:
24-10
device-internal
X1
+24V
+24V
0V
0V
K1 NC
K1 NC
AP5358F1.FH7
DC +24 V (21,6...26,4)
Via allowed voltage range
using internal protection
see page 4-8:
"Technical data –> Control
voltage connection for HDC"
DOK-DURADR-HDC01.1****-PR02-EN-P