X10, Ecoxexpansion Interface - Rexroth Indramat DURADRIVE SYSTEM200 Project Planning Manual

Drive controllers with degree of protection ip 65
Hide thumbs Also See for DURADRIVE SYSTEM200:
Table of Contents

Advertisement

DURADRIVE Drive Controllers

X10, EcoXexpansion interface

Illustration
Connection cross section
Connection of
expansion interface
DOK-DURADR-HDC01.1****-PR02-EN-P
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Note:
EcoX allows:
Technical data of connector
Fig. 4-91:
Connector X10
Design
Type
Spring contact
Fig. 4-92:
Design
Cross section
single wire
[mm²]
0.2-2.5
Fig. 4-93:
Connection cross section
Note:
Always use a shielded cable for connection. Connect the
shield to XS1, XS2 or XS3.
Expansion interface
device-external
Fig. 4-94:
Expansion interface
DURADRIVE HDC01.1 Drive Controller
synchronization of drives and I/O modules
connection of up to 2 modules with 16 digital inputs and
outputs each per drive controller
transmission of a command value from one drive
controllers to a maximum of three other drive controllers.
Ap5268f1.FH7
No. of pins
2 x 3
Cross section
multi core wire
[mm²]
0.2-1.5
device internal
X10
1
IAN+
2
IAN-
3
0V
4
IAN+
5
IAN-
6
0V
4-55
Design
Bushing on connector
Cross section
in AWG
gauge no.:
24-16
IAN+
IAN-
AP5376F1.FH7