11-10
Replacing or Exchanging Drive Components

Replacing the Firmware Module

Replacing the Programming Module (complete module)

LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
• Switch drive controller off
• Dismount protective cover
• Loosen screw at programming module and pull programming module
out
• Pull programming module out
• Open the lock on the back of the programming module
• Open the programming module
• Insert old parameter module into new firmware module
• Close lock (lock must be pushed outward)
• Insert programming module and screw on
• Mount protective cover
• Switch drive controller on
• Secure parameters (DriveTop)
• Switch drive controller off
• Dismount protective cover
• Loosen screw at programming module and pull programming module
out
• Insert new programming module
• Mount protective cover
• Switch drive controller on
• Load parameters