Cleaning The Drive Controller - Rexroth Indramat DURADRIVE SYSTEM200 Project Planning Manual

Drive controllers with degree of protection ip 65
Hide thumbs Also See for DURADRIVE SYSTEM200:
Table of Contents

Advertisement

12-8
Attachment

12.4 Cleaning the drive controller

LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
High electrical voltage!
⇒ Prior to cleaning switch off the drive controller.
Secure it against switching back on.
DANGER
Burns caused by hot parts with temperatures of
more than 30 °C!
⇒ Depending on the work load of the unit and the
ambient conditions, the housing and the power
WARNING
heatsink can be very hot. Before starting to work at
the unit, allow it to cool down and measure the
temperature.
Danger of damages!
⇒ Do not use cleaning tools with sharp edges.
⇒ Do not use aggressive cleaning agents like alcohol.
CAUTION
• Drive controllers with cooling fan unit only: Clean the cooling air inlet
using a brush or compressed air.
• Drive controllers with cooling fan unit only: Dismount the cooling air
guide (see page 11-4).
• Clean the heatsink and the air guides using a brush or compressed
air.
• Drive controllers with cooling fan unit only: Remount the cooling air
guide (see page 11-4).
DURADRIVE Drive Controllers