Display icon
#
Procedure
See also
Displaying details of the drive objects (Page 451)
18.10.2
Displaying details of the drive objects
Drive system diagnostics - details
The following information is displayed for the drive objects:
● Status display (r0002)
– The status display (parameter r0002) of the drive object is displayed.
● Missing enable signals (r0046)
– The enable signals are diagnosed except for the drive objects that do not have enable
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
Gray
Special charac‐
ters
1.
Select the "Diagnostics" operating area.
2.
Press the menu forward key and the "Drive system" softkey.
3.
The "Drive System Diagnostics" window opens.
The name of the selected drive object is displayed in the window title.
Press the "Drive object +" or "Drive object -" softkey.
The next (+) or previous (-) drive object is selected.
- OR -
Press the "Select drive unit" softkey.
The "Select Drive Unit" window opens.
4.
Select the desired drive unit via the drop-down list box and press "OK" to
confirm the selection.
signals (e.g. Control Unit). Missing enables are shown in a pane below the displays.
Meaning
The drive status could not be determined for this drive object.
Error when reading the data.
Service and diagnostics
18.10 Drive system
451