16.5
Creating an archive with original data
You can select this type of start-up in order to save the original status of the control. The files
are archived in the "original.arc" file.
The file is stored on the CompactFlash card in the Archives/Manufacturer directory.
If there is no "original.arc" file in the directory, it is recommended that an archive be generated
from the data of the original control state as delivered.
As for "Create start-up", control components can be saved individually or jointly.
Requirement
In order to save NC data, you require access level 2 (service).
To back up programs/workpieces, you require access level 6 (keyswitch position 1).
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
3.
Activate "Create PLC hardware upgrade archive (SDBs only)" and press
the "OK" softkey.
The "Create PLC hardware upgrade archive (SDBs only): Select Storage
Location" window opens.
4.
Select the desired storage location in the displayed data tree.
- OR -
Press the "New directory" softkey to create a separate directory.
The "New Directory" window opens.
5.
Enter the required name and press the "OK" softkey.
The directory is created below the created folder.
6.
Press the "OK" softkey.
The "Generate Archive: Name" window opens.
The file type of the archive is ARC and is displayed in the window. Enter
the desired name and press the "OK" softkey.
The archive is generated and stored in the selected directory.