Deviations during the comparison are identified by being color-highlighted:
● Red: missing or non-accessible components compared with the reference topology.
● Pink: components that deviate in their attribute values compared with the reference
topology.
● Blue: new components not contained in the reference topology.
Saving
Note
Manufacturer topology and reference topology can be created with access level 3 (user) or
higher and are always saved on the active DHCP server.
Default storage locations:
● Current topology (.xml or .csv):
The following storage locations are offered depending on the configuration:
– Network topology (storage location: HMI-data / data backups)
– Local drive
– Network drives
– USB
In CSV format, ";" is preset as a separator; it can be changed in sldgconfig.xml
● Reference topology:
/user(_base)/common/tcu/$soll
● Manufacturer topology:
/oem(_base)/common/tcu/$soll
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
3.
Press the "Save" softkey to save the current topology.
The "Save as" window opens.
4.
Position the cursor on the desired option box, specify a file name and
possibly a comment, and confirm with "OK".
Configuring the network
17.6 Station-related network diagnostics
403