14a.
14b.
a)
rack slides smoothly on the pinion.
b) slide the limit switch bracket along the rack in the opening direction until the limit switch trips. Now move the bracket at
lock it onto the rack with the provided captive bolts.
c) repeat the operation with the closed position limit switch.
FL200 > Par. 3.7 (Fig. 7). For other optional accessories, consult the respective instruction manuals.
3.6 - INSTALLING THE PHOTOCELLS model PH200 (Fig. 6a - 6b)
consult the instruction manual of the photocells.
them as close as possible to the gate (maximum distance = 15 cm) • a tube for passing the cables must be present in the
For the installation procedure see Fig. 6a - 6b.
3.7 - INSTALLING THE FLASHING LIGHT model FL200 (Fig. 7)
• The
• For connection to the Flash terminal,
the cable and sheath as shown in Fig. 8 .
to a horizontal or vertical surface.
For the installation procedure see Fig. 7 .
4
ELECTRICAL CONNECTIONS
4.1 - ELECTRICAL CONNECTION TO THE CONTROL UNIT (Fig. 8)
01. Perforate the rubber membrane and insert the cables necessary to connect the various devices (
40–50 cm long and secure them with cable ties ( Phase 02 - Fig. 8
02. Connect the various devices of the kit and any other components designed for being used on the system (optional and not
ge) (Phase 03 - Fig. 8
It is not necessary to observe any polarity, with the exception
the cable and sheath as shown in Phase 03 - Fig. 8
4.2 - POWER SUPPLY CONNECTION
• For operational and programming tests of the automation
long way from the automation, an extension may be used in this phase.
• For the testing and commissioning phase of the automation
01. Make sure that the gearmotor plug is not plugged into the wall socket.
02. Disconnect the power cable from the gearmotor' s power supply terminal (Fig.10/A FILO400START/FILO600START
03. Loosen the collar
04. Connect the power cable to the gearmotor's power supply terminal (Fig.10/B FILO400START/FILO600START
05. Tighten the collar to secure the electric cable.
06. Before closing the gearmotor's cover ( Fig. 9 ) it is possible to programme the control unit (see Chapter 5).
10
B
5 – English
A] on the rack ( Phase 13 - Fig. 5
C
Step
).
of the system to the mains power or
, use the cable supplied, inserting the plug into an electrical socket. If the socket is a
, it is necessary to connect the control unit permanently to the mains power supply,
A
)
of the shielded aerial cable, it is necessary to connect
Phase 01 - Fig. 8
of the shielded aerial cable which must be connected with
replacement of the cable supplied
) (Fig.11/A FILO400ST/AU01/FILO600ST/AU01
.
) (Fig.11/B FILO400ST/AU01/FILO600ST/AU01
11
B
least 2 cm further and
PH200
fastening point
FL200
included in the packa -
MUST be performed exclu
-
).
).
A
Need help?