Installation - Salicru SLC TWIN PRO2 T UL User Manual

6 and 10 kva
Table of Contents

Advertisement

5. INSTALLATION.

Read and respect the Safety Information, described
in Chapter 2 of this document. Failure to obey some
of the instructions described in this manual can result in a
serious or very serious accident to persons in direct contact
or in the vicinity, as well as faults in the device and/or loads
connected to it.
In addition to the device's own user manual, other docu-
ments are supplied on the CD-ROM or documentation pen
drive. Consult them and strictly follow the indicated pro-
cedure.
Unless otherwise indicated, all actions, instructions, guide-
lines and notes are applicable to the devices, whether or
not they form part of a parallel system.
5.1. RECEPTION OF THE DEVICE.
It is dangerous to handle the device on the pallet, as
it could overturn and cause serious impact injuries
to operators and/or entrapment. Pay attention to section
1.2.1. of the safety instructions -EK266*08- in all matters
relating to the handling, movement and siting of the unit.
Use the most suitable means to move the UPS while it is
packed, with a pallet jack or forklift.
Any handling of the device must be carried out in accordance
with the weights shown in the technical specifications
according to the model, indicated in Chapter '9. Annexes'.
5.1.1. Reception, unpacking and contents.
Reception. Check that:
The data on the label affixed to the packaging corre-
ˆ
sponds to that specified on the order. Once the UPS is
unpacked, check the previous data with those of the
device nameplate.
If there are discrepancies, report the issue as soon as
possible, citing the device's manufacturing number and
delivery note references.
It has not suffered any mishaps during transportation
ˆ
(packaging and impact indicator in perfect condition).
Otherwise, follow the protocol indicated on the label
attached to the impact indicator, located on the
packaging.
Unpacking.
To check the contents, it will be necessary to remove
ˆ
the packaging.
Complete the unpacking according to the proce-
dure of section 5.1.3.
Contents.
The device itself.
ˆ
The user manual in CD-ROM or pen drive format.
ˆ
1 communications cable.
ˆ
2 cables for parallel connection, current and signal bus.
ˆ
1 female connector for the connection of the external
ˆ
EPO, with an insulated cable functioning as a jumper
to close the circuit (inserted into its connector counter-
part).
Once the reception is completed, it is advisable to re-pack
the UPS until it is put into service in order to protect it
against mechanical shock, dust, dirt, etc.
USER MANUAL
The packaging of the device consists of a wooden pallet,
cardboard or wooden box, depending on the item, expanded
polystyrene corners, polyethylene cover and strapping, all
of which are recyclable materials. When the packaging
requires disposal, it must be carried out in accordance with
current laws.
We recommend keeping the packaging for at least 1 year.
5.1.2. Storage.
The device storage shall be done in a dry, ventilated place
and protected from rain, dust, water splashes or chemical
agents. It is advisable to keep each device and battery unit
in its original packaging, as it has been specifically de-
signed to ensure maximum protection during transportation
and storage.
For devices that contain Pb-Ca batteries, the
charging times indicated in Tab. 2 of document
EK266*08 regarding the temperature to which they are ex-
posed, must be respected, otherwise the warranty may be
invalidated.
After this period, connect the device to the mains together
with the battery unit if applicable, start it according to
the instructions described in this manual and charge for
12 hours.
In parallel systems, it is not necessary to interconnect de-
vices before battery charging. Each of them can be treated
independently to charge them.
Then shut down the device, disconnect it and store the UPS
and batteries in their original packaging, noting the new
date for recharging the batteries.
Do not store the devices where the ambient temperature
exceeds 50ºC or drops below -15ºC, as this may cause deg-
radation of the electrical characteristics of the batteries.
5.1.3. Unpacking.
The packaging of the equipment consists of wooden pallet,
carton or wood envelope according to cases, polystyrene
foamed corners [EPS] or polyethylene foam [EPE], polyeth-
ylene sheath and strap, all recyclable materials; so if you
are going to get rid of them you must do it according to the
laws in force. We recommend storing the packaging in case
it should be used in the future.
To unpack the device, follow the sequence in Figure 3 (cut
the straps of the cardboard packaging and lift it off as if it
were a cover or dismantle it with the necessary tools if it is
made of wood); remove the corners and plastic cover. This
will leave the UPS standing on the pallet.
SLC TWIN PRO2 T UL UNINTERRUPTIBLE POWER SUPPLIES (UPS)
13

Advertisement

Table of Contents
loading

Table of Contents