UNINTERRUPTIBLE POWER SUPPLY (UPS) + LIGHTING FLOW DIMMER STABILIZERS (ILUEST) + SWITCH MODE POWER SUPPLY + STATIC INVERTERS + PHOTOVOLTAIC INVERTERS + VOLTAGE STABILIZERS AND POWER LINE CONDITIONERS UNINTERRUPTIBLE POWER SUPPLY SPS.ADVANCE RT series USER'S MANUAL...
«Main protective earthing terminal» symbol. Connect the earth cable coming from the installation to this terminal. Yours sincerely. SALICRU «Earth bonding terminal». Connect the earth cable coming from the load and the external battery cabinet to this terminal. The equipment here described can cause important physical damages due to wrong handling.
«Off» (deactivated) it doesn't mean that at the output there will not be voltage. All outlets of the UPS has an earth bonding, duly connected SALICRU...
So, to do it, the input and static bypass switches will have to • Do not store, install or expose the equipment in corrosive, be turned «Off». wets, dusty inflammable or explosive environments and never outdoors. Put warnings of danger and/or emergency switches if the safety Standards require it in your particular installation.
Page 7
• Never short the battery terminals as it involves a high risk. It involves the detriment of the equipment and batteries. • Avoid mechanical efforts and impacts. • Do not open or mutilate the battery. Spilled electrolyte is harmful and toxic to the skin and eyes. SALICRU...
Quality and standard 2.3. Environment. guarantee. This product has been designed to respect the environment and has been manufactured in accordance with the standard ISO 14001. 2.1. Declaration of the management. Equipment recycling at the end of its useful life: Our company commits to use the services of authorised socie- Our target is the client’s satisfaction, therefore this Management ties and according to the regulations, in order to treat the recov-...
Plastic beauty front Plastic beauty front Front virew ADVANCE RT Fixing screws, Plastic beauty front Front view battery module for ADVANCE RT Fig. 1. Front view models from 0,7 to 10 kVA and battery modules for extended back up times. SALICRU...
Page 10
Output connector, with Módem USB COM / ADSL / Fax / ... protection port Standard 750 and IEC inlet for AC 1000 VA models power supply IEC outlets RS232 COM Earth connection Input connector, for modem / ADSL / Fax / ... line port for battery module IEC outlets...
3.3. Description and operating 3.3.1. Main features. principle. • Control by microprocessor with high reliability. • Design of high frequency. This user's manual describes the installation and operating of • Stabilizer with «Boost» and «Buck» technology. the Uninterruptible Power Supply (UPS) from SPS.ADVANCE • Selectable output range and line sensitivity.
The isolation transformer can be installed at the input or output of the UPS from SPS.ADVANCE RT series and it will always be located out from the equipment enclosure. 3.4.2. External maintenance manual bypass.
Installation. because due to its specification of isolation it will prevent the triggering of the protections fitted in the primary of the trans- former in case of electrical shock in the secondary (output of the isolation transformer). • Check the Safety instructions, from section 1.2.3. • Remind you that all external isolation transformers already installed or supplied from factory, has the neutral of the sec- • Check that the data in the nameplate are the required by the...
4.2.4. Vertical assembling -tower type- or rack. • All the UPSs from SPS.ADVANCE RT series are designed to assemble the equipment as tower format -vertical position of the equipment- or rack -horizontal position- for its installa- tion in 19"...
• To take out the beautiful front cover, proceed as follows (see figure 4): Remove the two fixing screws "C" from beautiful plastic front cover. Move the front cover to "D" direction, by applying a hard and moderated knock on its side (side without screws), to free the trim entered into the metallic frame.
Put a UPS in a rack cabinet, it is needed to have the side internal rail as support mode "C". In lack of them and under request, a rails can be supplied as a guide, to be SALICRU...
installed by the end user. Make the assembling at the required height, assuring the correct torque of the fixing screws. Face the equipment over the rails and enter it to the bottom. Depending on the model of the equipment and as a result of the weight, it is recommended to make the installation works by two persons, and even more when they are done on the top and bottom of the cabinet.
Anderson connector. This schuko plug to the AC mains outlet. connector is not available in models up to 1kVA. • For battery connection with the equipment, follow the stated steps in sections 4.2.4.4 and 4.2.4.6, keeping in mind the model. SALICRU...
• Through the control panel, it can be selected the reverse • Each battery module is independent for each equip- functionality, normally closed (NC). ment. It is completely forbidden to connect to equip- ments to the same battery module. Less punctual cases, it is not recommended to use this type of connection due to the function of the EPO button, because it would not work in case of any of the two cables that goes Minimum features of fast...
Fig. 10. AS400 dry contact pin-out. • Installation procedure: Go to website: Description Pin-out Input/output http://support.salicru.com UPS fault Output Choose the operating platform that you need and follow General alarm Output the instructions described in the web site to download the software.
Page 22
Nevertheless, when it is done, it will be done gradually to avoid any problem, as minimum in the first commissioning. • If inductive loads with big inrush current apart from sensi- tive ones are required to be connected like laser printers or CRT monitors, keep in mind the start inrush currents of these peripherals in order to avoid that the equipment becomes blocked under the worst conditions.
• Fan will be started up and the LCD from control panel will show the status of the equipment. • After several seconds, the UPS is established on "NORM" (Line mode). If the mains voltage is wrong, the UPS will shift SALICRU...
Control panel. • The following critical alarms do not allow deactivating the own acoustic alarm: Low battery, Fan fault, internal Over temperature in the equip- ment and battery fault or damaged. • The acoustic alarm can be deactivated when beeping, 6.1.
• To set the IEC outlet group through the LCD panel of the equipment, proceed as follows: 1.- Enter into the configuration mode. Press the key for more than 3 seconds and the UPS will shift to setting mode. SALICRU...
2.- Select the configuration elements. 3.- Validate the configuration element. Press the key to select the configurable elements When the LCD panel displays "GF", press the key stated in table 10 and go forward or backward till reaching more than one second to enter into the element to set.
1.2.3.3 side. • The equipment from SPS.ADVANCE RT series only requires Therefore, before doing any reparation or maintenance task, a minimum maintenance. The used battery in the standard the internal battery fuses and/or the interlink connections be- models is lead acid, sealed, VRLA and maintenance free.
7.2.2. FAQ. General indications. Problem Possible cause Solution The equipment doesn't start up when pressing Internal fuse blown. Consult with the S.T.S.. over the corresponding key. Jumpers at the output are not connected Connect the output jumpers. The equipment is ON but the loads do not properly.
Consult our Website to have more information 7.5. Technical service network. Coverage, both national and international, from our Service and Technical Support (S.T.S.), can be found in our Website. SALICRU...
(real time) samples are received, usually coming from an power but in alternating current can defer depending on the analogical/digital converter(ADC). power factor. • Power factor.- It is defined as power factor, p.f., of an alter- nating current circuit, as the ratio between the active power, SALICRU...
Page 32
• LCD.- LCD acronym of Liquid Crystal Display, device in- vented by Jack Janning, who was employee of NCR. It is an electric system of data presentation based on 2 transparent conductor layers and in the middle a special crystal liquid that have the capacity to orientate the light when trespassing.