Cylindrical lock

Advertisement

Profile Series v.G1 Cylindrical Lock
3. Frame Preparation for Strike
4. Latchbolt and Fire Stop Plate Installation
1. Install latch with beveled bolt facing the strike.
2. Attach with two screws but DO NOT tighten completely at this time.
3. Attach Fire Stop Plate with two screws.
Note: Required for all Fire Rated doors
Fire Rated Doors– Install Fire
Stop Plate (P/N 52-0033)
as shown below
/8" Dia. holes x 1/4" Deep
red
C L of
1-1/2" Dia.
e
1-1/2"
olt
A7755A.indd 5
Screws (2)
#8-32 x 3/4"
(2) 1/8" Dia. holes
required
7/8"
Fire
stop plate
(2) Self tapping
screws #8 x 1/2"
long for wood
& metal doors
Through-bolt
hole (2)
Centerline of
latch front and
strike
Non Fire Rated Exterior Doors–
Install Weather Conduit (P/N 52-2847)
as shown below
Hole for ribbon
cable from keypad
to controller
Slot
Inside
of door
Lockbody
hole
IMPORTANT: Latch bevel must match door bevel and
deadlocking latch must stop on strike when door is closed
800-810-WIRE (9473) • www.sargentlock.com • A7755A
Latchbolt
door prep
Pre-drilled
and/or tapped
holes 2 places
Strike
5
11/9/18 12:05 PM