Instructions for Installation of
Keypad Rim/Mortise Exit Devices
A7137C
Copyright © 2018, Sargent Manufacturing Company, an ASSA ABLOY Groupcompany.
All rights reserved. Reproduction in whole or in part without the express written permission of
Sargent Manufacturing Company is prohibited.
KP8877 and KP8878
KP8977 and KP8978
KP8877
KP8978

Advertisement

loading
Need help?

Need help?

Do you have a question about the SARGENT KP8977 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Assa Abloy SARGENT KP8977

  • Page 1 Keypad Rim/Mortise Exit Devices KP8877 and KP8878 KP8977 and KP8978 KP8877 KP8978 A7137C Copyright © 2018, Sargent Manufacturing Company, an ASSA ABLOY Groupcompany. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
  • Page 3: Table Of Contents

    Table of Contents Items Supplied...............1 Parts Breakdown..............2 Rim Installation Instructions for KP8800 Series....4 Mortise Installation Instructions for KP8900 Series..10 Programming Instructions..........19 Programming Instructions Française........ 23 Supplemental – Individual “Door” Log Sheet ....26 800-810-WIRE (9473) • www.sargentlock.com • A7137C...
  • Page 4: Items Supplied

    KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Items Supplied with Exit Device Items included in your KP8877 and KP8977 Series Exit Device carton: • Outside Escutcheon with Keypad • Outside motorized Trim Assembly • Exit Device •...
  • Page 5: Parts Breakdown

    KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Parts Breakdown ITEM # PART # DESCRIPTION *Outside Escutcheon Assembly (with keypad assy) 52-2340 52-0004 *Outside Escutcheon only 52-2299 Keypad (with ribbon cable) less escutcheon 52-2303 Screw Pack (Includes 1c, 1d, 2d, 2e) Fire Stop Plate 52-0033 01-1500...
  • Page 6 KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Parts Breakdown (Continued) ITEM # PART # DESCRIPTION 52-2340 *Outside Escutcheon Assembly (with keypad assy) 52-0004 *Outside Escutcheon only 52-2299 Keypad (with ribbon cable) less escutcheon 52-2303 Screw Pack (Includes 1c, 1d, 2d, 2e) 52-0033 Fire Stop Plate 01-1500...
  • Page 7: Rim Installation Instructions For Kp8800 Series

    KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Rim Installation Instructions for KP8800 Series NOTE: BEFORE STARTING • This device is non-handed • Door should be fitted and hung • Verify box label for size of exit device, function and hand •...
  • Page 8 KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Rim Installation Instructions for KP8800 Series (Continued) Step #2 Install Outside & Inside Trim 1. Outside Trim 2. Inside Trim • Route harness through under cut of cylinderhole • Route “ET” harness along track cutout for wood doors andac- and out to other side of door cess hole for metal doors •...
  • Page 9 KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Rim Installation Instructions for KP8800 Series (Continued) Step #3 Apply Fire Stop Plate 1. Fire stop plate for 12-devices • Fire stop plate required in all fire rated doors (12-) •...
  • Page 10 KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Rim Installation Instructions for KP8800 Series (Continued) Step #4 Outside Keypad Escutcheon Insert wires and connector from the outside of the door,through the fire stop plate (if required) Connector & Wires go through fire stop •...
  • Page 11 KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Rim Installation Instructions for KP8800 Series (Continued) Step #5 Inside Controller Assembly • Plug keypad connector into inside escutcheon as shown.The back Back- plate can be removed to feed the plate Keypad large connector through slot into...
  • Page 12 KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Rim Installation Instructions for KP8800 Series (Continued) Step #6 Rail Assembly Install rail according to installation instruction sheet A6770 Step #7 Battery Installation • Place (4) C size batteries into the compartment •...
  • Page 13 KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device NOTE: BEFORE STARTING • Check hand of door - this device is not reversible • Door should be fitted and hung • Verify box label for size of exit device, function and hand Left Hand Right Hand Reverse Bevel...
  • Page 14 KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Step #2 Install Outside & Inside Trim 1. Outside Trim 2. Inside Trim • Mount “ET” control onto door • Route “ET” harness along track cutout for wood doors and access hole for metal doors.
  • Page 15: Mortise Installation Instructions For Kp8900 Series

    KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Mortise Installation Instructions for KP8900 Series (Continued) Step #3 Apply Fire Stop Plate (Required for 12-) 5. Fire Stop Plate for 12- Devices • Fire stop plate required on all fire rated doors (12-) •...
  • Page 16 KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Mortise Installation Instructions for KP8900 Series (Continued) 6. Insert Wires and Connector • From the outside of the door through the Fire Stop Plate (if required) Wires & connector •...
  • Page 17 KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Mortise Installation Instructions for KP8900 Series (Continued) Step #5 Inside Controller Assembly • Plug Keypad connector into inside escutcheon as shown.The back Back- plate can be removed to feed the Keypad plate large connector through slot into...
  • Page 18 KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Mortise Installation Instructions for KP8900 Series (Continued) Installation Instructions for KP8900 Series (Continued) Step #6 Rail Assembly Install Rail according to installation instruction A6705 Step #7 Battery Installation • Place (4) C size batteries into the compartment •...
  • Page 19: Programming Instructions

    KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Programming Instructions The Keypad Exit Device Lock can support 100 users. Each user is assigned a User Number in addition to the code used for entry. Example: USER USER USER CODE TYPE NUMBER...
  • Page 20 KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Programming Instructions (Continued) To Enter the Supervisory Code: Yellow LED begins to blink slowly 99# Master Code Yellow LED blinks quickly 50# 1# 03# Supervisory Code Yellow LED blinks slowly Supervisory Code Yellow LED goes out To Enter a User Code:...
  • Page 21 KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Programming Instructions (Continued) To Interrogate Transaction Log: Last 15 Entries 99# Supervisory or Master Code Yellow LED begins to blink slowly 70# 0# 0# Yellow LED blinks slowly Yellow LED begins to blink quickly (Point printer at LED as shown) Yellow LED blinks (Printing starts) When finished printing, press sample transaction output...
  • Page 22 KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Programming Instructions(Continued) Chain Programming of the KP8800 and KP8900 Series Exit Device (including 12-) When programming multiple User Numbers and Codes into the Keypad Exit Device, it is not necessary to leave and re-enter the programming Mode (50) for each entry.
  • Page 23 KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Programming Instructions – Français Serrure à clavier KP Exits Device Guide de programmation La serrure à clavier peut accomoder 100 utilisateurs. On doit assigner à chacun un numéro d’utilisa- teur,en plus de son code d’entrée..
  • Page 24 KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Programming Instructions – Français Pour entrer un code passage (fonction maintenue): Entrer: 99# Code maître ou superviseur suivi de ** * code d’utilisateur suivi de Code d’utilisateur suivi de 50# 2# Numéro d’utilisateur (entre 04 et 97) suivi du # et La même code devra être utilisé...
  • Page 25 KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Programming Instructions – Français Programmation en chaîne: Pour programmer des numéros et des codes d’utilisateurs multiples, il n’est pas nésessaire de quitter le mode de promma- tion (50) entre chaque entrée. On peut entrer un après l’autre, en désordre, les trois différents types de codes d’utilisateurs (ordinaire, passage et une fois)..
  • Page 26: Supplemental - Individual "Door" Log Sheet

    KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device Supplemental – Individual “Door” Log Sheet (KP) Lock Model: Door Name: Location: Table 1: Main Codes – User Programmed “Door” Log Function User Number Default Code User Programmed Code Master Code 1234 Emergency Code...
  • Page 28 Copyright © 2018, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

This manual is also suitable for:

Sargent kp8877Sargent kp8878Sargent kp8978Sargent kp8977