68
5.2 Troubleshooting Using the Serial Interface
Communications
To qu ickly verify serial com m u nications send the
and receiving the help m enu , the serial com m u nications are verified . If fu rther problem s
persist, review Append ix B for m ore inform ation on com m u nications.
Verify Parameters
To verify the cam era setu p, send the
Verify Factory Calibrated Settings
To restore the cam era's factory settings send the
After execu ting this com m and send the
Verify Timing and Digital Video Path
Use the test pattern featu re to verify the proper tim ing and connections betw een the
cam era and the fram e grabber and verify the proper ou tpu t along the d igital processing
chain.
Verify Voltage
To check the cam era's inpu t voltages, u se the
w ithin the proper range (+12V to +15V). If a problem still persists, contact Technical
Su pport. See section Error! Reference source not found. for contact inform ation.
5.3 Specific Solutions
No Output or Erratic Behavior
If you r cam era provid es no ou tpu t or behaves erratically, it m ay be picking u p rand om
noise from long cables acting as antennae. Do not attach w ires to u nu sed pins. Verify that
the cam era is not receiving spu riou s inpu ts (e.g. EXSYN C, if cam era is u sing an internal
signal for synchronization).
Line Dropout, Bright Lines, or Incorrect Line rate
Verify that the frequ ency of the internal sync is set correctly.
03-032-10216-06
All manuals and user guides at all-guides.com
h
(help) com m and . By send ing the
gcp
(get cam era param eters) com m and .
rfs
com m and .
gcp
com m and to verify the factory settings.
vv
com m and . Make su re the voltage is
Piranha 3 User Manual
h
Teledyne DALSA