Returning Calibration Results and Errors

Returning All Pixel Coefficients
Purpose:
Syntax:
Syntax Elements:
N otes:
Example:
Returning FPN Coefficients
Purpose:
Syntax:
Syntax Elements:
Example:
Setting a Range of FPN Coefficients
Purpose:
Syntax
Syntax Elements:
Notes:
Example:
Teledyne DALSA
All manuals and user guides at all-guides.com
Returns all the current pixel coefficients in the ord er FPN, PRNU,
FPN, PRNU... for the range specified by x1 and x2. The camera
also returns the pixel number w ith every fifth coefficient.
dpc x1 x2
x1
Start pixel to d isplay in a range from 1 to sensor pixel
count.
x2
End pixel to d isplay in a range from 1 to sensor pixel
count.
This function returns all the current pixel coefficients in the
ord er FPN, PRNU, FPN, PRNU... The camera also returns the
pixel number w ith each coefficient.
dpc 10 20
Returns a pixel's FPN coefficient value in DN (12 bit LSB)
gfc i
i
The pixel number to read in a range from 1 to sensor
pixel count.
gfc 10
Sets a range of pixel FPN coefficients.
sfr x x i
x
The first pixel number of the range.
x
The last pixel number of the range.
i
Coefficient value in a range from 0-2048.
The first pixel of the range must be less than the last.
sfr 1 100 80