Transmit Check Character
** Transmit Check Character
Do Not Transmit Check Character
Set Length Range for MSI-Plessey
The scanner can be configured to only decode MSI-Plessey barcodes with lengths that fall between (inclusive) the
minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.
Set the Minimum Length (Default: 4)
Set the Maximum Length (Default: 60)
Example: Set the scanner to decode MSI-Plessey barcodes containing between 8 and 12 characters:
1. Scan the Set the Minimum Length barcode.
2. Scan the numeric barcodes "0" and "8" from the "Digit Barcodes" section in Appendix.
3. Scan the Set the Maximum Length barcode.
4. Scan the numeric barcodes "0" and "C" from the "Digit Barcodes" section in Appendix.
69