Error Codes

When you apply power to the fixture, it runs a calibration (homing) sequence and displays any
errors that it detects.
Example:
there is an error in channel 1. When multiple errors are present they will cycle on the
display twice, and then the fixture will reset (restart). Any errors that remain after two
reset cycles are not correctable by reset alone and will require service. Please contact
support if detailed assistance is needed.
Blade Rot Wheel
This message displays after the reset of the fixture if any of the following conditions exist:
the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
the stepper motor is defective or the related IC driver on the main PCB has failed
the Blade Rotation movement is not located in the default position after the reset
Color Wheel
This message displays after the reset of the fixture if any of the following conditions exist:
the fixture head's magnetic-indexing circuit malfunctions (optical or magnetic sensor
failure)
the stepper motor is defective or the related IC driver on the main PCB has failed
the Color wheel movement is not located in the default position after the reset
CMY Wheel
This message displays after the reset of the fixture if any of the following conditions exist:
the fixture head's magnetic-indexing circuit malfunctions (optical or magnetic sensor
failure)
the stepper motor is defective or the related IC driver on the main PCB has failed
the CMY movement is not located in the default position after the reset
CTO Wheel
This message displays after the reset of the fixture if any of the following conditions exist:
the fixture head's magnetic-indexing circuit malfunctions (optical or magnetic sensor
failure)
the stepper motor is defective or the related IC driver on the main PCB has failed
the CTO movement is not located in the default position after the reset
Focus Wheel
This message displays after the reset of the fixture if any of the following conditions exist:
the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
the stepper motor is defective or the related IC driver on the main PCB has failed
the Focus movement is not located in the default position after the reset