Restore Factory Defaults; Error Codes; Specifications And Reference - ETC ColorSource Spot V 1.0 Installation Manual

Table of Contents

Advertisement

ETC Installation Guide
ColorSource Spot V1.0

Restore Factory Defaults

Press and hold the Mode button, Up button, and Down button
simultaneously for 5 seconds. The DMX start address will blink once to
confirm that defaults have been restored.

Error Codes

These error codes may display on the user interface.
CAL
: Screen toggles between
with the color calibration. The fixture will need to be returned to the
ETC factory; contact your local dealer to set up a repair.
OtP
: Screen toggles between
fixture has gone into over-temperature protection mode to avoid
damaging the fixture. If the error does not clear, contact
ETC Technical Support (visit etcconnect.com/contactETC).
No App
upgraded fixtures have a software issue. Reload software to clear
the error. If the error persists, contact ETC Technical Support (visit
etcconnect.com/contactETC).

Specifications and Reference

For current and complete compliance and specifications, see the
ColorSource Spot V datasheet at etcconnect.com.
Environment
Maximum recommended ambient operating temperature: Ta = 40°C 
(104°F)
Maximum anticipated external surface temperature at 40°C
ambient: Tmax = 80°C (176°F)
External temperatures after 5 minutes of full-brightness operation at
25°C (77°F) ambient: 30°C (86°F)
External Temperature (steady state achieved) at 25°C (77°F): 37°C
(99°F)
Electrical
Operates between 100 V and 240 VAC at a frequency of 50/60 Hz,
or at 208 VAC L-L.
Maximum power consumption is 245 W.
Up to 7 luminaires (15 A max) may be linked via power thru
connector (8 luminaires total per circuit) when used with an
R20 Relay Module or Unison Echo Relay Panel. Consult breaker trip
curves when used with other equipment. Requires power from a
non-dimmable source.
Inrush:
120 V: 55 A (first half-cycle)
-
240 V: 59 A (first half-cycle)
-