Specifications

Environmental specifications

Specification
System inlet temperature (standard operating
1
support
Operating
Nonoperating
Relative humidity (noncondensing)
Operating
Nonoperating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 305 m (1.8°F per 1,000 ft) to 3,050
m (10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The
upper limit and rate of change might be limited by the type and number of options installed. Under standard operating
support, a fan fault or the ambient temperature exceeding 30°C (86°F) might result in reduced system performance
issue.

Limited system operating temperature requirements

The maximum system operating temperature for most components installed in the server is 35°C (95°F).
However, some components in specific configurations are subject to thermal limitations. To ensure safe
and reliable system operation, observe the limited operating temperature for these configurations.
Temperature requirements for transceiver installation in the QSFP port
The following temperature values are valid for systems that have a homogenous node configuration.
Marvell ThunderX2
processor model
CN9975-2000 (150 W TDP) No
CN9980-2200 (180 W TDP) No
Value
OCP network
QSFP port cable
adapter present
type
──
Yes
Copper
Yes
Fiber optic
──
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
8% to 90%
28°C (82.4°F), maximum wet bulb temperature
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
Maximum inlet ambient
temperature
35°C (95°F)
35°C (95°F)
27°C (80.6°F)
23°C (73.4°F)
Table Continued
Specifications
45