System Battery Replacement; System Battery Information; Removing And Replacing The System Battery - HPE AR44z User Manual

Table of Contents

Advertisement

System battery replacement

System battery information

The server contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery
that provides power to the real-time clock. If this battery is not properly handled, a risk of the fire and
burns exists. To reduce the risk of personal injury:
Do not attempt to recharge the battery.
Do not expose the battery to temperatures higher than 60°C (140°F).
Do not disassemble, crush, puncture, short external contacts, or dispose the battery in fire or water.
If the server no longer automatically displays the correct date and time, then replace the battery that
provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.

Removing and replacing the system battery

Procedure
1.
Power down the server on page 14.
2.
Disconnect all peripheral cables from the server.
3.
Remove the server on page 14.
4.
Locate the battery on the system board.
5.
Slightly push the metal tab, and then remove the system battery from the socket.
6.
Slightly push the metal tab, and then install the new system battery in the socket.