Datafox ZK-MasterIV Manual page 92

Table of Contents

Advertisement

Manual Datafox ZK-MasterIV
Display
40
41
42
43
44
45
Table 19: Digital Output
Display
GIS
Digital input 1 is low
60
Digital input 1 is high
61
Digital input 2 is low
62
Digital input 2 is high
63
Digital input 3 is low
64
Digital input 3 is high
65
Digital input 3 was interrupted
66
Digital input 3 was short-circuited
67
not used
70
not used
71
not used
72
not used
73
not used
74
not used
75
Table 20: Digital Input
Version: 04.01.07.00
Assigned status message
Digital output 1 is low (off)
Put digital output 1 on high (on)
Digital output 1 is trigger (on for given period of time)
Digital output 2 is low (off)
Put digital output 2 on high (on)
Digital output 2 is trigger (on for given period of time)
Assigned status message
Page 92
PHG
IO-Box closed
IO-Box open
IO-Box closed
IO-Box open
sabotage supervision -> communication
channel OK
sabotage supervision -> communication
channel interrupted
PHG not used
PHG not used
Digital input 1 reader low
Digital input 1 reader high
Digital input 2 reader low
Digital input 2 reader high
Alarm control panel -> state of device
OK
Alarm control panel -> device
manipulated
www.datafox.de

Advertisement

Table of Contents
loading

Related Products for Datafox ZK-MasterIV

Table of Contents