Datafox ZK-MasterIV Manual page 79

Table of Contents

Advertisement

Manual Datafox ZK-MasterIV
Alias
Data type
ID
Number
(int)
RefGroup
Number
(int)
RefTime
Number
(int)
Number
RefTimeNoPin
(int)
Table 12: Location table (defines which card groups get access to which room at which time)
Alias
Data type
ID
Number
(int)
Weekdays
Number
(int)
TimeStart
String
(Time)
TimeEnd
String
(Time)
Table 13: Time table (grouping of single time zones (weekday from to) as a time model number)
Alias
Data type
Day
String
(Date)
RefGroup
Number
(int)
RefTime
Number
(int)
Table 14: Holiday table (setting of blocking days like holidays or company holidays)
Alias
Data type
RefReader
Number
(int)
PortIn
Number
(int)
RefAction
Number
(int)
RefTime
Number
(int)
Table 15: Event table (assigning an action to a signal at the digital input)
Version: 04.01.07.00
Description
Length
4
ID of the room. All other tables refer to this data line via
this number, if necessary.
4
Reference to the identification table. Labels the access
authorized group. All cards of this group have access to
this room.
4
The time model in which authorized persons get access. (0
= not used)
4
The time model to which an additional PIN does not need
to be entered (at peak times etc.).
Description
Length
4
ID of the time model. All other tables refer to this data
line via this number, if necessary.
7
Indicates the weekdays on which the following period of
time should be applied to (form: 7 digits at most 1-7 e.g.
134567 = Monday, Wednesday till Sunday)
5
The start time for the period of time. (form: 24h HH:MM)
5
The ending time for the period of time.
Description
Length
10
Date of the blocking day. (form: YYYY-MM-DD)
4
Indicates the authorization group to which the blocking
day is applied.
A zero defines a global validity for all groups.
4
Indicates the assigned time model. (0 = not used) During
this time access is granted. Thus, also "'half holidays"' like
New Year's Eve can be realized.
Description
Length
4
Module (door module or master) on which is the digital
input.
1
Number of the digital input on the module.
4
Reference to the action that should be carried out (e.g.
switch relay).
4
The time model which indicates when the digital input is
checked. (0 = not used)
Page 79