Each action that should be activated has to be entered in the table Action. The table Action refers to
the tables Reader and Time. In the table Reader the module is left on which the relay or the Open
Collector is to be switched. The reference to the table Time indicates when the switch shall be done. If
start and stop time are entered, the relay is switched on when exceeding the start time and switched
off when exceeding the stop time. The entry of the duration E lapse in the table Action is ignored. If
the relay should only be activated for a few seconds, e.g. for a buzzer control, the stop time has to be set
on "'00 : 00"'. If the start time is exceeded, the respective exit will be switched for X seconds (RefTime
in Action table). The entry E lapse in the table Action now indicates the on-time.
Example:
¦
A buzzer is to be activated for
16.00. The buzzer is controlled by the internal relay of the ZK-MasterIV.
¦
The heating system is to be turned on the "'day mode"' at
7 pm
19.00
on all weekdays. The corresponding relay is at the door module with the bus number 2.
Reader.txt
; ID ZM TM RefLocation RefAction PinGeneral
1
1 320
0
2
1 020
0
T ime.txt
; ID Weekdays TimeStart TimeEnd
3 12345
10:00
4 12345
16:00
5 1234567
07:00
Action.txt
; ID RefRead PortOut E lapse RefTime
6
1
1
7
1
1
8
2
1
Version: 04.01.07.00
seconds from Monday to Friday at
3
0
0
0
0
00:00
00:00
19:00
15
3
15
4
0
5
07.00
Page 87
10.00
am and 4 pm
am and on the "'night mode"' at
www.datafox.de