Example: Wiring of a mantrap
A door is controlled via an internal door module with integrated reader TMR33-TMR and an external ac-
cess reader TMR33-TR as mantrap In this case the internal door module is connected to the ZK-MasterIV
via a RS485 bus. The external access reader is connected to the internal door module with a RS232 stub.
The door opening is controlled via the relay integrated in the door module TMR33-TMR. In this case the
door module with the relay is in the secure area and the external access reader without a relay is in the
insecure area.
Figure 48: Wiring of a mantrap
Note:
£
• Connection for electricity supply via power supply unit or bell transformer.
• Install the door-opener in the protected area when using it for exterior doors.
• At closed door contact aprox. 15 mA are used up at 12 V = 0,18 Watt. This
Version: 04.01.07.00
Please note the hints for the calculation of the cable cross-section and the
cable length.
means a consumption of aprox. 1,6 kWh per year.
Page 69
www.datafox.de