P C X 2 5 6 I N S T A L L A T I O N M A N U A L
1 0 . 7 E x t e r n a l T a g R e a d e r ( P C X - P R O X / E X T )
A maximum of 7 can be installed on to the PCX 256 system and the maximum arm points are 30.

10.7.1 Connecting the PCX-PROX/EXT

470Ω Resistor
connected to
the control panel
and to the device
which is furthest
away
10.7.2 Programming the RED LED to follow a PGM.
The RED LED on the PCX-PROX/EXT can be programmed so that it follows an output.
To achieve this, go to 'CHANGE OUTPUTS' and then 'Reader PGMs' and program the first PGM
output (PGM1) to whichever type is required.
For example you may want the Prox to show the system armed, therefore you can use the output
"0204: Final Arm A". The RED LED will then be illuminated once Partition A has armed.