Chapter 6 Description of parameter setting
P429
Constant-speed torque limiting time
Setting Range:0~999.9S
P430
Width of arrive of frequency in hqsteretic loop
Setting Range:0~2.00S
This parameter sets frequency reached width, for details, refer to P425-F426
introductions
P431
Jump Frequency 1
Setting Range:0~frequency upper limit
P432
Jump Frequency 2
Setting Range:0~frequency upper limit
P433
Jump frequency hysteresis loop width
Setting Range:0~2.0
If machine resonance occurred at a certain frequency, we can use the
frequency jump function to skip the resonance point. t!20OtJ support 2 jump
6
frequencies by parameter P431 and P432.
Frequency jump hysteresis loop width can be set through P433 as below:
Unit:0.1
Unit:0.1
78
FC100 Series User Manaul
Default value 0.5
Unit:0.1
Default value 0
.5
Unit:0.1
Default value 0
Default value 0
Default value 0.5
Unit:0.1
Need help?
Do you have a question about the FC100 Series and is the answer not in the manual?