FC100 Series User Manaul
P117

Initialization of parameters

SettingRange:0-8Unit:1
Explanation: 8: Initialization of parameters
When the parameter setup is not proper or when false running leads to improper
setup of parameter, you can set P117 at 08 to restore all parameters to the
Factory Setting, and then you can set them again according to actual need.
Attention: when locked up of parameters is valid, that is when P118=1, you
cannot carry out initialization of parameters and change them. Please unlock
first, and then set these parameters.
P118
Initialization of parameters
SettingRange:0-1Unit:1
Explanation: 0: unlocked
1: Locked
You can lock the parameter by P118 to prevent unexpected change of the
inverter setup.
When P118 is valid, all the other parameters except P100 (main frequency
setting) cannot be changed.
Group P2: Parameters of basic applications
P200

Start mode selection

SettingRange:0-1Unit:1
Explanation: 0: Start at start frequency
1: Tracing start
There are two start modes for FC100 series inverter. You can choose from the
two by setup of parameter P200 and the condition of machinery.
0: Start at start frequency
Most loads do not have special requirement in start. Inverter output from the start
frequency.
Chapter 6 Description of parameter setting
Factory Setting: 0
Factory Setting: 0
Factory Setting: 0
51
6