Siemens SIMATIC S7-1500 Function Manual page 98

Web server
Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

Toolbar of the trend diagram
As in STEP 7, the buttons on the function bar of the trend diagram provide you with tools for
adjusting the display.
The following table shows the Web server buttons in the trend diagram toolbar:
Table 3- 8
Buttons of the trend diagram toolbar
Symbol
Function
Open / add measurement
Save as
Undo move / zoom
Repeat move / zoom
Snapshot
Move view
Zoom selection
Vertical zoom selection
Horizontal zoom selection
Zoom in
Zoom out
Scaling
Restore standard view
Display all
Scale X automatically
Scale Y automatically
Web server
Function Manual, 11/2019, A5E03484625-AG
Description
Opens measurements or adds measurement to an existing mea-
surement.
Saves measurement(s) as a file with the extension .csv, .wtrc
(SIMOTION format for saving Trace data) or .ttrecx (TIA Portal
format for saving Trace data).
In addition to the measured data the command also saves the
diagram, snapshots, marking and calculated signals.
Undoes the move / zoom function executed last. If you have car-
ried out several move / zoom functions, you can undo these step-
by-step.
Redoes the last undone move / zoom function. If you have undone
several move / zoom functions, you can redo these step-by-step.
Saves the current view as a snapshot (see the section "Settings
and displays of the Snapshot symbol").
Moves the display with a pressed mouse button - corresponds to
the
button in STEP 7.
Selection of an arbitrary range with the mouse button pressed. The
button scales the display to the range selection.
Selection of a vertical range with the mouse button pressed. The
button scales the display to the range selection.
Selection of a horizontal range with the mouse button pressed.
The button scales the display to the range selection.
Enlargement of the display. The ranges of the X axis and Y axis
are reduced every time the button is clicked. The curves are dis-
played larger.
Reduction of the display. The ranges of the X axis and Y axis are
reduced every time the button is clicked. The curves are displayed
smaller.
Scales all the signals or also only signal / signal group vertically
and horizontally.
The button undoes scaling and move commands. The view is
reset to the status at the time of loading of the measurement. Hid-
den signals are also reset but remain disabled.
The button moves all the signals completely into the display area
without changing the relative positions of the signals to each other.
Automatic scaling of all visible signals on the horizontal X area.
Automatic scaling of all visible signals on the vertical Y area.