3.13 Record
The following table shows the settings and displays for the measurements:
Column
Alignment of the measurements
Trigger/Sample
Time stamp (absolute time)
Table columns
Name
Alignment
Offset
Time stamp
Comment
Shortcut menu commands
"Save as WTRC"
"Save as CSV"
"Edit name"
"Edit offset"
"Edit comment"
"Delete measurement"
104
Description
Alignment of the measurements in accordance with the trigger or measurement point.
The individual zero point for the measurement is predefined in the table under the "Align-
ment" column.
Alignment of the measurements in accordance with their time stamp.
The signals are aligned in accordance with the time from the absolute time stamp.
Static display of the measurement icon
Display and change options for the name
Note that the name must be unique.
Alignment of the measurement (only adjustable with the "Trigger/Sample" check box selec-
ted).
Determines the individual zero point for a measurement. All signals for the measurement
are displayed in relation to this zero point.
The following settings are possible:
Trigger
•
First sample after the trigger event
•
First sample
•
Last sampling
•
Offset related to the time axis
Moves the measurement left or right by the offset stated on the time axis.
If you enter solely a numerical value without a unit of measurement, the system automati-
cally assigns the unit "ms" (for example 0=0ms, 100=100ms, 1000=1s, -1001=-1s 1ms ,
LT#2000ms=2s, LT#-3605000ms=-1h 5s , LT#-1h5s=-1h 5s )
Display of the trigger time
Display and input option for a comment about the signal
Saves the measurement(s) as a file with the extension .csv, .wtrc (SIMOTION format for
saving Trace data) or .ttrecx (TIA Portal format for saving Trace data).
Exports a measurement as a file with the file extension .´csv.
Note that the command only saves the measured data. The command does not save the
diagram, snapshots, markings and calculated signals.
Switches the name in editing mode
Switches the offset in editing mode
Switches the comment in editing mode
Deletes the measurement
Function Manual, 11/2019, A5E03484625-AG