Reading And Displaying Data From The Cpu - Siemens SIMATIC S7-1500 Function Manual

Web server
Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

Implementation
The user page uses AWP commands to read out values from the CPU as well as writing
values to it. The user page also uses AWP commands for the definition of enum types, such
as the assignment of tags to enum types for handling the ON/OFF settings.
The user page is structured as follows:
Figure 3-75
In addition, the user page uses an AWP command that writes the special tag to the tag table.
The tag table contains the ID of the user who is currently accessing the page.
3.16.5.2

Reading and displaying data from the CPU

Example of HTML code for reading and displaying data from the CPU
This part of the HTML code is used to display the power output on the user page.
Web server
Function Manual, 11/2019, A5E03484625-AG
Header of the website with number and location of the wind turbine.
Atmospheric conditions at the turbine, wind speed, wind direction and current temperature are
displayed.
Read-out power output.
Manual override: Activates manual override of the turbine. To make manual settings for speed,
orientation and angle of attack, the STEP 7 user program requires that manual override has
been activated.
Override of the orientation: Activates manual override of the turbine orientation.
Override of the angle of attack: Activates manual override of the angle of attack of the rotor
blades.
By clicking this button, you transfer the override settings to the CPU.
Manual setting of a percentage value for braking. The setting "Manual override" is not required
to enter a brake value.
Overview of user page wind turbine
Web pages
3.16 User pages
145