Zone Functions Of Scb-10 - DeDietrich AMC Pro 45 Service Manual

Control panel & high efficiency wall-hung gas boiler
Hide thumbs Also See for AMC Pro 45:
Table of Contents

Advertisement

7 Installation examples
5 Room temperature sensor - circuit A
6 Domestic hot water tank pump
7 Mixing valve - circuit B
8 Pump and safety thermostat - circuit B
9 Mixing valve - circuit A
10 Pump and safety thermostat - circuit A
11 System sensor 1
12 System sensor 2
13 Domestic hot water sensor
14 Flow sensor - circuit C
7.3

Zone functions of SCB-10

Tab.22
Parameter setting for zone function
Zone
Parameter to set zone function
0 = Disable
1 = Direct
2 = Mixing Circuit
3 = Swimming pool
4 = High Temperature
5 = Fan Convector
6 = DHW tank
7 = Electrical DHW
8 = Time Program
9 = ProcessHeat
10 = DHW Layered
11 = DHW Internal tank
(1) The number refers to the circuit number which can be set with the rotary dial on the SCB-10.
(2) With AD249 option.
(3) The last number of the parameter is related to the zone. The code can be used to identify the parameter settings in the connection
examples.
Fig.30
Rotary dial
X2
X3
28
AMC Pro
The SCB-10 with the AD249 option has following basic functions with
default zone settings:
CIRCA1 with parameter CP020 set as Direct circuit
CIRCB1 with parameter CP021 set as Disable
DHW1 with parameter CP022 set as Disable
CIRCC1 with parameter CP023 set as Disable
AUX1 with parameter CP024 set as Disable
To configure your specific installation, make sure to check and adjust the
parameter settings for the selected zones. The zone function table shows
which parameter settings are available for which zones.
CIRCA 1
CIRCB 1
(1)
CP020
CP021
(3)
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
You can use the rotary dial to identify multiple SCB-10s, for example in a
cascade situation. The default position of the rotary dial is 1. In this case
zone A will appear in the display as CIRCA1 (circuit A 1).
AD-3001318-01
15 Flow sensor - circuit B
16 Flow sensor - circuit A
17 Impressed current anode
18 Connectors Mod-BUS
19 Coding wheel, selects the generator number in the
cascade in Mod-Bus
20 S-BUS connector
21 END connector for L-BUS connection
22 L-BUS connection to control unit (CU-GH08)
23 S-BUS cable connector
DHW 1
(1)
(1)
CP022
(3)
(3)
x
x
x
x
x
x
CIRCC 1
AUX 1
(1)(2)
CP023
CP024
(3)
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
7725087 - v.01 - 06062019
(1)(2)
(3)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amc pro 65Amc pro 90Amc pro 115

Table of Contents