6 Installer instructions

6
Installer instructions
6.1

Accessing the installer level

Fig.13
Installer level
00:12
........ .......
........ ......... ...
..... ... ....... .... .. ..... ....... .... ..... .......
i
........ .......
0
0
0
1
1
1
2
2
2
3
3
3
4
4
4
5
6.2

Configuring the installation at installer level

Tab.13
CU-GH08
Icon
Zone or function
CIRCA / CH
Gas fired appliance
Tab.14
SCB-10
Icon
Zone or function
CIRCA
CIRCB
DHW
CIRCC
0-10 volt input
Digital Input
Analogue input
Cascade management B
Buffer Tank Schedule
Outdoor temperature
Status information
Tab.15
Configuring a zone or function of CU-GH08 or SCB-10
Parameters, counters, signals
Parameters
Counters
Signals
Adv. Parameters
18
AMC Pro
0
1
2
3
4
5
6
AD-3001378-02
Description
Central heating circuit
Gas boiler
Description
Central heating circuit A
Central heating circuit B
Domestic hot water external circuit
Central heating circuit C
0–10 volt input signal
Digital input signal
Analogue input signal
Management of a cascade of multiple boilers
Enable a buffer tank with one or two sensors
Outdoor sensor
PCB SCB-10 status information
Description
Set the parameters at installer level
Read the counters at installer level
Read the signals at installer level
Set the parameters at advanced installer level
Some parameters that may affect the operation of the boiler are protected
by an access code. Only the installer is allowed to modify these
parameters.
1. Select the tile [
].
2. Press the
button to confirm the selection.
3. Use the rotary knob to select code: 0012.
4. Press the
button to confirm the selection.
When the installer level is enabled, the status of the tile [
changes from Off into On.
5. To leave the installer level, select the tile [
6. Use the rotary knob to select Confirm or Cancel.
7. Press the
button to confirm the selection.
When the installer level is disabled, the status of the tile [
changes from On into Off.
When the control panel is not used for 30 minutes, the installer level is left
automatically.
Configure the installation by pressing the
Installation Setup
. Select the control unit or circuit board you want to
configure:
]
] .
]
button and selecting
7725087 - v.01 - 06062019