Connection Example 4 - DeDietrich AMC Pro 45 Service Manual

Control panel & high efficiency wall-hung gas boiler
Hide thumbs Also See for AMC Pro 45:
Table of Contents

Advertisement

7 Installation examples
Fig.38
1 boiler + 1 direct zone + 1 mixing zone + domestic hot water (DHW) zone
1
A
X12
N
X13
B
N L
N
9
6
A Boiler
B Direct zone - CircA1
Important
For this configuration an additional PCB (accessory AD249) is placed on connector X8 of the SCB-10 PCB.
36
AMC Pro
X9
X10
SCB-10
X8
X1
C
N L
N L TS
7
X15
A
N L TS
N
N L
TS
5
3
2
7.6.5

Connection example 4

B
2
X2
L-BUS
X11
SP
RS
S-BUS
X14
Status
C
B
0-10V
+
-
T out
4
3
2
1
R-Bus
R-Bus
R-Bus
1
X14
1
2
C
B
Tsyst Tsyst Tdhw Tflow Tflow Tflow
8
10
4
C Mixing zone - CircB1 (underfloor heating)
D DHW zone - DHWA (layered calorifier - 2 sensors)
7
C
3
4
T
5
9
10
6
M
A
X3
X131
CB-03
X5
X03
X4
R-Bus
BL
RL
A
A
TA
+TA-
7725087 - v.01 - 06062019
D
8
AD-4100037-01
X136
Tout
Tdhw
AD-4100139-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amc pro 65Amc pro 90Amc pro 115

Table of Contents