Cleaning The Condensate Collector - DeDietrich AMC Pro 45 Service Manual

Control panel & high efficiency wall-hung gas boiler
Hide thumbs Also See for AMC Pro 45:
Table of Contents

Advertisement

Fig.65
Open clicker flue gas pipe
2
1
Fig.66
Remove flue gas pipe
Fig.67
Remove siphon
6
7
7725087 - v.01 - 06062019
9.4.2
1. Remove the return sensor connector.
2. Remove the flue gas temperature sensor (if connected)
3. Open the clicker from the flue gas pipe.
4. Push the upper part of the telescopic flue gas pipe down as far as
4
3
AD-4000128-01
5. Pull up the flue gas pipe and remove it.
5
AD-4000129-01
6. Remove the siphon.
7. Place a bucket under the boiler.
AD-4000130-01

Cleaning the condensate collector

possible.