Tab.77
Navigation for basic installer level
Level
Menu path
Basic installer
(1) See the column "Submenu" in the following table for the correct navigation. The signals are grouped in specific functionalities.
Tab.78
Signals at basic installer level
Code
Display text
AM001
DHW active
AM010
Pump speed
AM011
Service required? Is service currently required?
AM015
Pump running?
AM016
System Flow
Temp
AM018
T return
AM019
Water pressure
AM022
On / Off heat
demand
AM027
Outside
temperature
AM033
Next Service Ind.
AM037
3 way valve
AM040
Control
temperature
AM046
Internet T.Outside Outside temperature received from an internet
AP078
Out sensor
detected
GM001
Actual fan RPM
GM002
Fan RPM setpoint Actual fan RPM setpoint
GM008
Actual flame
current
Tab.79
Navigation for installer level
Level
Menu path
Installer
(1) See the column "Submenu" in the following table for the correct navigation. The signals are grouped in specific functionalities.
7725087 - v.01 - 06062019
> Installation Setup > CU-GH08 > Submenu
Description
Is the appliance currently in domestic hot water
production mode?
The current pump speed
Is the pump running?
Flow temperature of appliance.
Return temperature of appliance. The
temperature of the water entering the
appliance.
Water pressure of the primary circuit.
On / Off heat demand
Instantaneous outside temperature
Next service indication
Status of the three way valve
Temperature used for hot water control
algorithms.
source
Outside sensor detected in the application
Actual fan RPM
Actual flame current measured
> Installation Setup > CU-GH08 > Submenu
8.3.3

Control unit signals

> Parameters, counters, signals > Signals
(1)
> Parameters, counters, signals > Signals
(1)
Range
0 = Off
1 = On
0 % - 100 %
0 = No
1 = Yes
0 = Inactive
1 = Active
-25 °C - 150 °C
-25 °C - 150 °C
0 bar - 4 bar
0 = Off
1 = On
-60 °C - 60 °C
0 = None
1 = A
2 = B
3 = C
4 = Custom
0 = CH
1 = DHW
0 °C - 250 °C
-70 °C - 70 °C
0 = No
1 = Yes
0 Rpm - 12000 Rpm
0 Rpm - 12000 Rpm
0 µA - 25 µA
8 Settings
Submenu
Gas fired
appliance
Gas fired
appliance
Gas fired
appliance
Gas fired
appliance
Producer Generic
Gas fired
appliance
Gas fired
appliance
Gas fired
appliance
Gas fired
appliance
Outdoor
temperature
Gas fired
appliance
Gas fired
appliance
Gas fired
appliance
Gas fired
appliance
Outdoor
temperature
Outdoor
temperature
Gas fired
appliance
Gas fired
appliance
Gas fired
appliance
AMC Pro
79