Verifying The Power Input Connections Before Applying Power; Connecting The Administration Console - Sun Microsystems SPARC Enterprise M4000 Installation Manual

Hide thumbs Also See for SPARC Enterprise M4000:
Table of Contents

Advertisement

3.2.2
Verifying the Power Input Connections Before
Applying Power
Have the site electrician verify that the input power source fulfills the power
requirements.
Refer to the SPARC Enterprise M4000/M5000 Servers Site Planning Guide for input
power requirements.
Note – The server end of the power cords should have been connected prior to
shipment (for servers preinstalled in an equipment rack) or when the server was
mounted in the equipment cabinet. If the server ends of the power cords were not
connected previously, connect them before continuing.
3.3

Connecting the Administration Console

The serial port on the XSCF Unit is a RJ-45 interface port used to monitor the boot
process and to modify the default settings. The port is monitored and configured
using an administrative console connected to the serial port by a serial cable.
You can monitor and configure the XSCF Unit using any one of the following
devices as the administrative console:
ASCII terminal
Workstation
Terminal server (or patch panel connected to a terminal server)
Personal computer
Note – It is possible to connect to the LAN ports using Telnet or ssh access. The
LAN ports have class-B private address values but they will not send out a packet
by themselves until configured.
Note – The modular connector (RCI connector) is not for connection to TNV circuits
See item 1 in Figure 3-2.
FIGURE 3-2
3-4
SPARC Enterprise M4000/M5000 Servers Service Manual • November 2008
shows the locations of the ports on the XSCF Unit.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc enterprise m5000

Table of Contents