Using the showstatus Command

The showstatus displays the information concerning the server's degraded FRUs.
An asterisk (*) which indicates that the unit has been degraded is displayed along
with any of the following states:
Faulted
Degraded
Deconfigured
Maintenance
An example of the showstatus output.
XSCF> showstatus
FANBP_C Status:Normal;
*
FAN_A#0 Status:Faulted;
XSCF>
B.2.4

Using the fmdump Command

The fmdump command can be used to display the contents of any log files associated
with the Solaris fault manager.
This example assumes there is only one fault.
#
fmdump
TIME UUID SUNW-MSG-ID
Nov 02 10:04:15.4911 0ee65618-2218-4997-c0dc-b5c410ed8ec2 SUN4-8000-0Y
B.2.4.1
fmdump -V Command
You can obtain more detail by using the -V option, as shown in the following
example.
# fmdump -V -u
TIME
Nov 02 10:04:15.4911 0ee65618-2218-4997-c0dc-b5c410ed8ec2 SUN4-8000-0Y
100% fault.io.fire.asic
FRU: hc://product-id=SUNW,A70/motherboard=0
rsrc: hc:///motherboard=0/hostbridge=0/pciexrc=0
B-6
SPARC Enterprise M4000/M5000 Servers Service Manual • November 2008
0ee65618-2218-4997-c0dc-b5c410ed8ec2
UUID
SUNW-MSG-ID