Sun Microsystems SPARC Enterprise M4000 Installation Manual page 54

Hide thumbs Also See for SPARC Enterprise M4000:
Table of Contents

Advertisement

TABLE B-2
Troubleshooting Method
Check LEDs
Check log files
Check using the XSCF
Shell
B.2
Using the Diagnostic Commands
The following commands are detailed in this section.
"Using the showhardconf Command" on page B-2
B.2.1
Using the showhardconf Command
The showhardconf command displays information about each FRU. The following
information is displayed:
Current configuration and status
Number of installed FRUs
Domain information
IOBOX information
Name properties of PCI cards
B-2
SPARC Enterprise M4000/M5000 Servers Service Manual • November 2008
Types of Troubleshooting Methods
Description
The system LEDs (on the operator panel) indicate any system or
hardware error detected during initial diagnosis or system
operation. Additional LEDs are provided on the XSCF Unit, power
supply unit, fan unit, and other units so that you can always locate
faulty components and identify specific errors.
System messages are often displayed on the system console. These
messages can alert you to system problems, such as a device that is
about to fail.
You can use the XSCF Shell to find details of an error state, the
device status history, and other status information.