See
"SPARC Enterprise M4000 Server Views" on page A-2
XSCF Unit on the SPARC Enterprise M4000 server.
3.3.1
Connecting the Console
This section explains how to physically connect and configure the console.
1. Connect the administrative console to the serial port using the serial cable that
shipped with the server.
2. Configure the settings on the administrative console.
The console should have the following settings:
Baud rate: 9600 bps
■
Data length: 8 bit
■
Parity: None
■
Stop: 1 bit
■
Flow control: None
■
Delay: Except for 0
■
3. Set the key on the operator panel to the Service position.
The Service position is indicated by an icon that looks like a wrench, the Locked
position is indicated by an icon that looks like a lock. (
FIGURE 3-3
For more details on the operator panel see
10.
4. Turn on the input power.
Refer to the manual that shipped with the input power source for instructions.
5. Watch the administration console for error messages as the XSCF Unit powers on.
See
Appendix B
3-6
SPARC Enterprise M4000/M5000 Servers Service Manual • November 2008
Operator Panel Mode Switch
for fault installation information.
for the location of the
FIGURE 3-3
"Operator Panel Overview" on page A-
)