Hold Cycle During Operation - Taylor C043 Operator's Manual

Frozen custard machine
Hide thumbs Also See for C043:
Table of Contents

Advertisement

Step 10
Open the draw arm plate.
Figure 39
Note: A chattering noise indicates that not enough
mix is entering the freezing cylinder. It may be
necessary to increase the flow of mix into the
freezing cylinder. Increase the flow control knob only
1/2 a number at a time. It takes 3 - 5 minutes to see
the results of the adjustment. (Whenever an
adjustment is made, first turn the adjustment knob
all the way to "5" and then back to the desired
number.)
Step 11
Continue to run the frozen custard into the holding
cabinet until the desired amount is obtained. Adjust
the mix flow as needed to maintain proper product
consistency. For maximum capacity, make sure the
hopper is full and the flow is adjusted as high as
possible within the acceptable product temperature
range.
Figure 40
Model C043
Step 12
When the desired amount is obtained and more
custard will be made later, follow the "Hold Cycle
During Operation" instructions starting on page 23.
Step 13
Repeat these steps for the remaining freezing
cylinders.

Hold Cycle During Operation

Step 1
Place the flow adjustment knob in the CLOSE
position. Set the timer for one minute.
Step 2
After one minute has expired, place the refrigeration
switch in the HOLD position for custard.
23
Figure 41
Figure 42
150629
Operating Procedures

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents