Sanitizing - Taylor C043 Operator's Manual

Frozen custard machine
Hide thumbs Also See for C043:
Table of Contents

Advertisement

Sanitizing

Step 1
Using lukewarm water, prepare an approved 100
PPM sanitizing solution (examples: 5 gal. [19 liters]
of Kay-5R or 4 gal. [15 liters] of Stera-SheenR).
USE WARM WATER AND FOLLOW THE MANU-
FACTURER'S SPECIFICATIONS.
Step 2
Place the feed tube and the flow control rod flat on
the bottom of the hopper.
Figure 18
Step 3
Place the product chutes in the hopper.
Figure 19
Step 4
Make sure the draw arm plate is closed and the
short door stud nuts are snug.
150629
Operating Procedures
Step 5
Attach the splash guards to the door studs.
Step 6
Make sure the refrigeration switch and the hopper
refrigeration switch are in the OFF position.
IMPORTANT! Refrigeration should NOT be on
when water is present in the freezing cylinder or
hopper.
18
Figure 20
Figure 21
Figure 22
Model C043

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents