j 5. Follow all lubricating procedures as outlined in
"Assembly".
j 6. If your unit is air cooled, check the condenser
for accumulation of dirt and lint. Dirty
condensers will reduce the efficiency and
capacity of the unit. Condensers should be
cleaned monthly with a soft brush. Never
use screwdrivers or other metal probes to
clean between the fins.
Note: For units equipped with an air filter, it
will be necessary to vacuum clean the filters
on a monthly schedule.
Caution: Always disconnect
electrical power prior to cleaning the
condenser. Failure to follow this instruction
may result in electrocution.
j 7. If your unit is water cooled, check the water
lines for kinks or leaks. Kinks can occur when
the unit is moved back and forth for cleaning
or maintenance purposes. Deteriorated or
cracked water lines should be replaced only
by an authorized Taylor distributor.
Model C043

Winter Storage

If the place of business is to be closed during the
winter months, it is important to protect the freezer
by following certain precautions, particularly if the
building is subject to freezing conditions.
Disconnect the freezer from the main power source
to prevent possible electrical damage.
On water cooled freezers, disconnect the water
supply. Relieve pressure on the spring in the water
valve. Use air pressure on the outlet side to blow out
any water remaining in the condenser. This is
extremely important. Failure to follow this
procedure may cause severe and costly damage to
the refrigeration system.
Your local Taylor Distributor can perform this winter
storage service for you.
Wrap detachable parts of the freezer such as
beater, blades, beater shaft, and freezer door, and
place them in a protected dry place. Rubber trim
parts and gaskets can be protected by wrapping
them with moisture-proof paper. All parts should be
thoroughly cleaned of dried mix or lubrication which
attract mice and other vermin.
It is recommended that an authorized service
technician perform winter storage draining, to insure
all water has been removed. This will guard against
freezing and rupturing of the components.