To The Installer; Electrical Hook-Up Installation; For 60 Cycle, 1 Phase, Supplied With Cord And Plug - Taylor 142 Operating Instructions Manual

Little softy soft serve freezer
Hide thumbs Also See for 142:
Table of Contents

Advertisement

Section 1
These machines are designed for indoor use only.
DO NOT install the machines in an area where
a water jet could be used. Failure to follow this
instruction may result in serious electrical shock.
Air Cooled Units
Air cooled units require a minimum of 6" (152 mm) of
clearance on both sides and 4" (102 mm) of clearance
on the bottom of the freezer. To prevent warm exhaust
from recirculating, place the rear of the unit against the
wall. This will allow adequate air flow across the
condenser.
Electrical Connections
Each freezer requires one power supply for each data
label. Check the data label(s) on the freezer for fuse,
circuit ampacity and electrical specifications. Refer to
the wiring diagram provided inside of the electrical box,
for proper power connections.
In the United States, this equipment is intended to be
installed in accordance with the National Electrical
Code (NEC), ANSI/NFPA 70-1987. The purpose of
the NEC code is the practical safeguarding of persons
and property from hazards arising from the use of
electricity. This code contains provisions considered
necessary for safety. Compliance therewith and
proper maintenance will result in an installation
essentially free from hazard! In all other areas of the
world, equipment should be installed in accordance
with the existing local codes. Please contact your local
authorities.
Stationary appliances which are not equipped with a
power cord and a plug or other device to disconnect
the appliance from the power source must have an
all-pole disconnecting device with a contact gap of at
least 3 mm installed in the external installation.
This equipment is provided with a grounding lug
that is to be properly attached to the rear of the frame
by the authorized installer. The installation location is
marked by the equipotential bonding symbol (5021 of
IEC 60417-1) on the removable panel and the frame.
Model 142

To the Installer

CAUTION: This equipment must be
properly grounded! Failure to do so can result in
severe personal injury from electrical shock!
Electrical Hook‐up Installation
For 60 Cycle, 1 PH, Supplied With Cord and Plug
This equipment is supplied with a 3‐wire cord and
grounding type plug for connection to a single phase,
60 cycle, branch circuit supply. This unit must be
plugged into a properly grounded receptacle. The cord
and plug provided for 115/60/1 and 208‐230/60/1 is 15
amp.; therefore the wall outlet must also be 15 amp.
Check the data label located on the rear of the freezer
for electrical specifications.
IMPORTANT: In order to secure the compressor and
to minimize vibration during shipment, two shipping
bolts have been added to the base pan of the unit.
Before installation, these bolts must be removed.
Permanent wiring may be used if local codes require
it. Instructions for conversion to permanent wiring are
as follows:
IMPORTANT: This procedure must be
performed by a qualified electrician.
1.
Be sure the freezer is electrically disconnected.
2.
Remove the appropriate panel and locate the
control box at the back of the freezer.
3.
Remove the factory‐installed cord and strain
relief bushing.
4.
Route incoming permanent wiring through 7/8"
(22 mm) hole in base pan.
5.
Connect two power supply leads, attach ground
(earth) wire to the grounding lug inside the
electrical box.
6.
Be sure unit is properly grounded before
applying power.
FOLLOW YOUR LOCAL ELECTRICAL CODES!