2.3)

Procedure notes

Prior to maintenance or service work, make absolutely sure to comply with the
stated safety instructions.
WARNING: Principally ensure the following at each maintenance event
CAUTION: The ignition is switched on, as long as the ground-cable
At maintenance of cooling, lubricating and fuel system take care without fail that
no contamination, metal chips, foreign material and/or dirt enters the system.
WARNING: Always allow engine to cool down to outside air temperature
Before re-using parts, clean, check and refit them per relevant instructions.
CAUTION: Generally, all metal parts are cleaned with a suitable cleaning
Before each re-assembly check units for missing parts. Only use adhesives,
lubricants, cleaning agents and solvents indicated in the maintenance instruc-
tions. If not respected, damage may be the consequence.
Effectivity: 912 Series
AIRCRAFT ENGINES
MAINTENANCE MANUAL
- Ignition „OFF" and system grounded,
- Disconnect battery
- Secure engine against unintentional operation.
At maintenance work which requires ignition „ON" and battery
connected, take care of the following:
- Secure the propeller against unintentional turning by hand
and
- Secure and observe propeller zone.
This precautionary measure serves to avoid any injuries in case
of an unintentional start of the engine. Non-compliance can
result in injuries or death.
(P lead) is not properly connected to ground.
before start of any work.
Severe burns and scalds may result if this is not respected.
agent.
05-00-00